All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)

The insulation upgrading of current 10kV overhead station is the most important concern related to the safe operation of distribution network. Compared with the newly built overhead station, upgrading of the current overhead station can be complemented through the combination of factory prefabrication and on-site all-enclosed connector.

All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)

The insulation upgrading of current 10kV overhead station is the most important concern related to the safe operation of distribution network. Compared with the newly built overhead station, upgrading of the current overhead station can be complemented through the combination of factory prefabrication and on-site all-enclosed connector.
All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)
All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)
All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)
All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)
All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)
All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)
All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)
All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)
All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)
All-Enclosed Pole-Mounted Overhead Station (Upgrading Project)

Product introduction:

The upgrading project is to replace the station equipment with totally enclosed disconnect switch, totally enclosed drop-out fuse cutout, totally enclosed arrester and pre-insulated clamps, on the basis of existing overhead station. This is the simplest and most reliable way to speed upgrade the station for good equipment insulation, shortening power outage time.

The 10kV all enclosed overhead station upgrading project follows the concept of overall design standardization, independent functional module, and flexible equipment exchange. It comprehensively considers the reliability, construction cost, operation and maintenance habits of the overhead station equipment set, as well as the standardization and interchangeability of various components, to meet the development trend of constructing international higher distribution network lines. It is of great significance to improve the quality of the distribution network and improve work efficiency.

Note: Technical datas and sketches are only for your reference. Such details in our contact prevail.

Technical parameter:


Disconnet switch
Technical data
TypeRated voltage(kV)Rated current(A)1min power frequency withstand voltagelightning impulse withstand voltageRated short-time withstand  current(kV/S)Rated peak withstand current(kV)
Phase to phase and phase to ground(kV)Between contacts(kV)Phase to phase and phase to ground(kV)Between contacts(kV)
GFW1-12/S630-2012630505512513020/450


Fuse cutout
technical data
TypeRated voltage(kV)Rated current(A)1minpower frequency withstand voltageLightning impulse withstand voltageRated breaking current
(kA)
Insulator material
Phase to phase and phase to ground(kV)Between contacts(kV)Phase to phase and phase to ground(kV)Between contacts(kV)
GHRW12-100/12.512100505812513012.5Polymer


Lightning Arrester
Technical data
TypeRated voltage
(kV)
Continuous operating voltage
(kV)
DC Voltage reference (1mA)     
(kV)
Nominal  current
(kA)
Residual voltage≤(kV)4/10μs high current impulse withstand current 
(kA)
2ms Impulse rectangular current
(A)
1/10 steep wave impulse current8/20lightning impulse current30/60 operating impulse current
HY10WZ-17/451713.6241051.84538.3100400


Pre-insulated clamps for equipment
Technical data
Installation positionTypeCross-sectional area of conductor
(mm
2
Operating voltage
(kV)
Wire stripping length
(mm)
Rods
(mm)
Bolts AF
(mm)
HV side of arresterSBJ-12D/2P-1HT-M1035-951035M1017
Power side and load side of disconnect switchSBJ-12B-3HT-M20×1.550-951035M20×1.517
Power side and load side of fuse cutoutSBJ-12B-2HT-M16×250-951035M1617
HV side of transformerSBJ-12B-M1250-951035M1217


Pre-insulated parallel groove clamp
Installation positionTypeTrunk-Copper or Alu(mm2)Branchs-Alu(mm2Branchs-Copper(mm2Bolt's number
Ground down lead of overhead linesJBG35-120/35-12035-12035-12035-701
JBG95-240/35-12095-24035-12035-1201