Product introduction:
The upgrading project is to replace the station equipment with totally enclosed disconnect switch, totally enclosed drop-out fuse cutout, totally enclosed arrester and pre-insulated clamps, on the basis of existing overhead station. This is the simplest and most reliable way to speed upgrade the station for good equipment insulation, shortening power outage time.
The 10kV all enclosed overhead station upgrading project follows the concept of overall design standardization, independent functional module, and flexible equipment exchange. It comprehensively considers the reliability, construction cost, operation and maintenance habits of the overhead station equipment set, as well as the standardization and interchangeability of various components, to meet the development trend of constructing international higher distribution network lines. It is of great significance to improve the quality of the distribution network and improve work efficiency.
Note: Technical datas and sketches are only for your reference. Such details in our contact prevail.
Technical parameter:
Disconnet switch Technical data |
Type | Rated voltage(kV) | Rated current(A) | 1min power frequency withstand voltage | lightning impulse withstand voltage | Rated short-time withstand current(kV/S) | Rated peak withstand current(kV) |
Phase to phase and phase to ground(kV) | Between contacts(kV) | Phase to phase and phase to ground(kV) | Between contacts(kV) |
GFW1-12/S630-20 | 12 | 630 | 50 | 55 | 125 | 130 | 20/4 | 50 |
Fuse cutout technical data |
Type | Rated voltage(kV) | Rated current(A) | 1minpower frequency withstand voltage | Lightning impulse withstand voltage | Rated breaking current (kA) | Insulator material |
Phase to phase and phase to ground(kV) | Between contacts(kV) | Phase to phase and phase to ground(kV) | Between contacts(kV) |
GHRW12-100/12.5 | 12 | 100 | 50 | 58 | 125 | 130 | 12.5 | Polymer |
Lightning Arrester Technical data |
Type | Rated voltage (kV) | Continuous operating voltage (kV) | DC Voltage reference (1mA) (kV) | Nominal current (kA) | Residual voltage≤(kV) | 4/10μs high current impulse withstand current (kA) | 2ms Impulse rectangular current (A) |
1/10 steep wave impulse current | 8/20lightning impulse current | 30/60 operating impulse current |
HY10WZ-17/45 | 17 | 13.6 | 24 | 10 | 51.8 | 45 | 38.3 | 100 | 400 |
Pre-insulated clamps for equipment Technical data |
Installation position | Type | Cross-sectional area of conductor (mm2) | Operating voltage (kV) | Wire stripping length (mm) | Rods (mm) | Bolts AF (mm) |
HV side of arrester | SBJ-12D/2P-1HT-M10 | 35-95 | 10 | 35 | M10 | 17 |
Power side and load side of disconnect switch | SBJ-12B-3HT-M20×1.5 | 50-95 | 10 | 35 | M20×1.5 | 17 |
Power side and load side of fuse cutout | SBJ-12B-2HT-M16×2 | 50-95 | 10 | 35 | M16 | 17 |
HV side of transformer | SBJ-12B-M12 | 50-95 | 10 | 35 | M12 | 17 |
Pre-insulated parallel groove clamp |
Installation position | Type | Trunk-Copper or Alu(mm2) | Branchs-Alu(mm2) | Branchs-Copper(mm2) | Bolt's number |
Ground down lead of overhead lines | JBG35-120/35-120 | 35-120 | 35-120 | 35-70 | 1 |
JBG95-240/35-120 | 95-240 | 35-120 | 35-120 | 1 |
Appearance size: